TM 11-5835-241-13&P
level for 10 volts.
(35) Adjust RECORD LEVEL control for +3 VU on VU meter.
(36) Record 60 seconds of this signal.
level for 10 volts.
(38) Adjust RECORD LEVEL control for -3 VU on VU meter.
(39) Record 60 seconds of this signal.
level for 10 volts.
(41) Adjust RECORD LEVEL control for -9 VU on VU meter.
(42) Record 60 seconds of this signal.
level for 10 volts.
(44) Adjust RECORD LEVEL control for -9 VU on the VU meter.
(45) Record 60 seconds of this signal.
(46) Rewind tape.
(47) Connect distortion analyzer to EXTENSION SPEAKER jack
across a precision (1%) 8-ohm resistor.
(48) Observing distortion analyzer in VTVM mode, while play-
ing back the 1000 Hz recorded signal, adjust PLAY LEVEL for 4 volts
This sets recorder output
as indicated on distortion analyzer meter.
for 2 watts at 1000 Hz reference.
(49) Rewind tape and measure distortion at all recorded
Do not change setting of PLAY LEVEL control. Measured
frequencies.
distortion should not exceed 5%.
FREQUENCY RESPONSE TEST.
f.
(1) Connect signal generator to MIC jack.
(2) Set SPEED control for 7.5 i.p.s.
5-23