TM 11-5835-241-13&P
(toward front and outer edge of chassis) and place cable clamp and
lockwasher on screw and secure using threaded spacer instead of nut.
(8) Remove nut and lockwasher from adjacent corner of
motor housing (toward front and center of chassis), place terminal
strip on screw, and secure using the lockwasher and nut.
(9) Install reel pedestal on motor shaft and tighten set
screw.
(10) Reconnect motor power leads as tagged in step (1).
REMOVAL AND REPLACEMENT OF VU METER
a. Unsolder meter, meter negative lead (center terminal).
Remove two screws and lockwashers holding meter and meter
b.
positive lead to mounting bracket, then remove meter through top of
chassis.
c. To replace meter, place meter through hole in chassis and
attach meter and meter positive terminal lead to mounting bracket
using screws and lock washers removed in step b.
Reconnect and solder meter, meter negative lead (center
d.
terminal]
e. Reinstall top panel and replace chassis in case.
5-8. REMOVAL AND
REPLACEMENT OF
COUNTER
Slip counter drive belt off counter drive pulley.
b.
c. Remove nut and lockwasher which attaches meter terminal
strip and remove terminal strip from screw.
Remove two screws (from top of chassis) and remove counter
d.