TM 32-5835-001-24 & P
Table 2-1. Organizational Preventive Maintenance Checks and Services
Interval
Procedures
Check for and have repaired
Item to be
Item
or adjusted as necessary
M
Inspected
No.
Q
WARNING
Be sure power supply is disconnected
from power source when performing
VOLTAGE may be present at the power
connector connected to POWER connec-
tor J2. This HIGH VOLTAGE could cause
death.
Power Supply
x
1
supply from case. Check power supply and
case for evidence of water, corrosion, and
damaged components. Clean and replace
fuses as necessary. For component damage,
forward to your direct support maintenance
Inspect waterproof gasket for leaks and
2
x
Gasket
worn or loose edges. Gaskets must be
clean, flexible and in good condition. If
gaskets are defective, direct support
Fuses
Check fuses for correct value, and that
x
3
holders are clean and in good condition.
4
x
Connectors
that they are not damaged and intact. Be
sure that attached wires within cable con-
nectors are not broken, frayed or under
undue strain. Forward to direct support
x
Knobs and Switches While making the operating checks, make
5
sure that mechanical action of each control
and switch is smooth and does not bind in-
ternally or externally. Make sure knobs
are tight on shafts. Forward to direct sup-
port maintenance unit for repair and adjust-
2-8